Castelle Office Direct OfficeDirect Storage Server Installation Manual Page 98

  • Download
  • Add to my manuals
  • Print
  • Page
    / 284
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 97
5 - 6 Sage Intergy 7.00 Install Guide Sage
Chapter 5: Database Tuning
To determine the number of virtual processors in a Windows system, open the
Windows Task Manager. In the View menu, make sure that the CPU history shows
one graph for each processor.
Other server arguments - This field contains command line arguments that should
be changed by the installing technician. For all installs, enter the text
-basetable 1 -tablerangesize 1500 -shmsegsize 256 -napmax 250 to
set database timing and allow for logging of performance statistics.
Service name or Port # - Set this value to ‘Intergy-db’ with no quotes.
Maximum Servers per Broker - Accept the default value for this field. This value is
typically zero.
Maximum Clients per Server - This value determines the number of client
connections allowed for each remote client server process. In most cases, the default
value of 4 should not be changed. On Sage Intergy servers with limited memory, this
number can be increased to allow for more client connections at the expense of
slower performance. This value may also need to be changed when setting the
maximum servers value.
Minimum Clients per Server - This value should always be set to 1.
Auto Calculate - Select this checkbox to activate the automatic calculation of the
Maximum Users and Maximum Servers fields. Use automatic calculation for Sage
Intergy 7.00 whenever possible.
Maximum users - This setting represents the maximum number of database
connections, as opposed to the literal number of users. This is because client
workstations may establish multiple database connections when functions such as
reporting and imaging are used. This value is automatically configured when the Auto
Calculate checkbox is selected, and should be entered manually only for n-tier
environments or other special configurations of Sage Intergy.
When manually calculating this value, round up to the nearest integer value. Make
sure the maximum users setting is always larger than the multiplied product of the
Maximum Servers and the Maximum Clients Per Server values.
For sites where Intergy is installed without SIEHR, the base formula is
300 + (1.1 x 2a) where a is the number of serialized Sage Intergy users.
If SIEHR is installed and serialized, then the formula is 300 + (1.1 x 2a) + (1.1 x b/4)
where a is the number of serialized Sage Intergy users and b is the number of
serialized SIEHR users.
Example: A customer site has fifty Sage Intergy users and forty SIEHR users
serialized. The formula would be 300 + (1.1 x 2 x 50) + (1.1 x 40/4). The resulting value
of 421 would be entered in the Maximum Users field.